Features
·
4
line, 16 character LCD
·
Optical
sensor to control backlight of LCD
·
Pressure
status warning LED’s
·
Configurable
display
·
CAN
interface
·
Unit
available with either analogue outputs or external switch and audible warning
control lines
Electrical
·
Supply
voltage 8 to 16Vdc
·
Supply
current 150mA max @12V typical, 170mA @12V max
·
CAN
bus 2.0B active, 1Mbps
Mechanical
·
Weight
less than 0.5lb (without antenna)
·
Aluminium
alloy housing, anodised and dyed black
Environmental
·
Unit
sealed with o-rings and screws sealed with silicon rubber
·
Maximum
humidity 100%
·
Operating
temperature 10 to +50°C
·
Vibration
5 to 2000Hz @ 5g, 2 hours
|
Connection Definition
·
Connector
ASDD206-09PN-HE (Audible warning variant)
|
Pin 1
Pin 2
Pin 3
Pin 4
Pin 5
Pin 6
Pin 7
Pin 8
Pin 9
|
Supply +ve
Power ground
CAN -
CAN +
Audible control line
External switch
Ground
N/C
N/C
|
·
Connector
ASDD206-09PN-HE (Analogue variant)
|
Pin 1
Pin 2
Pin 3
Pin 4
Pin 5
Pin 6
Pin 7
Pin 8
Pin 9
|
Supply +ve
Power ground
CAN -
CAN +
Signal ground
Analogue signal 1
Analogue signal 2
Analogue signal 3
Analogue signal 4
|
·
Antenna
connector SMA socket
|
Case
Centre
|
RF ground
RF in
|
|